Oxford Method Research Programme

Drawings ( on-line Library )

G0 0 010   External cladding sheet locations 900 structural zone
G0 0 020   External cladding - sheet locations 1200 structural zone
G0 0 030   External cladding - sheet locations 1500 structural zone
G0 0 040   Cladding fixings - lap joints
G0 0 045   Cantilever conditions
G0 0 046   Cladding overlap conditions
G0 0 110   Brick cladding - 2400 room zone key sections
G0 0 111   Brick cladding 2700 room zone key sections
G0 0 112   Brick cladding perspective key to block junctions
G0 0 113   Brick cladding elevation key to details (2400 zone)
G0 0 114   Brick cladding elevation key to details (2700 zone)
G0 0 115   Brick cladding key plan (grd floor level)
G0 0 116   Brick cladding key plan to details (upper floor level)
G0 0 117   Plan of recessed door (Key to re-entrant details)
G1 1 010   Cladding conditions - lap joint
G1 1 011   Coping at external corner
G1 1 012   Coping at internal corner
G1 1 020   Block junction conditions (diagramatic)
G1 1 030   Block junction conditions
G1 1 031   Block junction conditions
G1 1 035   Block junction condition - internal corner ('A' type)
G1 1 036   Block junction condition 'T' junction (B & C type)
G1 1 040   Top and bottom fixings for multibeams - plans
G1 1 041   Top and bottom fixings for multibeams - sections
G1 1 050   Cladding at cill level
G1 1 051   Cladding under full height window - GL
G1 1 060   Cladding at intermediate floor slab level
G1 1 072   Cladding at roof level in line block junction - inverted roof
G1 1 075   Cladding at block junction
G1 1 080   External corner plan within structural zone
G1 1 081   External plan within room zone
G1 1 085   External corner plan - lap joint
G1 1 090   Internal corner plan - room zone
G1 1 100   Plan at intermediate column floor or roof zone
G1 1 112   Plan of special coping at junction between movement joint and roof perimeter
G1 1 114   Elevation of special coping at junction between movement joint & perimeter
G1 1 120   Cladding at re-entrant corner with column
G1 1 130   Cladding at re-entrant corner without column
G1 1 140   Movement joint in cladding at room zone level
G1 1 150   Movement joint in cladding at roof level
G1 1 260   Cladding supports (brick)
G1 1 261   Cladding supports (brick)
G1 1 262   Cladding supports (steel)
G1 1 270   Cladding supports
G1 1 271   Cladding supports
G1 2 010   Flashing for cladding
G1 2 011   Flashings & pressings for cladding
G1 2 012   Cill support angles (galvanised)
G1 2 015   Isometric of preformed external corner
G1 2 020   Block junction flashing - components
G2 1 010   Window sub-frame details
G2 1 011   Window sub-frame details
G2 1 012   Window sub frame details fixings
G2 1 017   Elevation of window sub-frame
G2 1 020   Plan details of window inserts
G2 1 030   Sectional details of window inserts - fixed
G2 1 032   Sectional details of window inserts V.S.
G2 1 041   Plan of roller awning blinds
G2 1 055   External glazed dloors (with transom section)
G2 1 057   External door - section at block junction
G2 2 075   Door subframe components
G2 2 080   Plantroom door - components
G4 0 016   Brick cladding - key plan to details (upper floor level)
G4 1 101   Section through coping
G4 1 102   Coping at "T" block junction
G4 1 103   Coping at in-line block junction
G4 1 104   Coping at int/ext corner block junction
G4 1 105   Plan of coping at movement joint
G4 1 108   Plan of external corner in structural zone
G4 1 109   Plan of internal corner in structural zone (with bottom boom connection to stud)
G4 1 110   Plan of internal corner in structural zone (without bottom boom connect to stud)
G4 1 111   Plan of ext wall at column in structural zone (with bottom boom connect to stud)
G4 1 112   Plan of ext wall at column in st/zone (w/out bottom boom connection to stud)
G4 1 113   Plan of external wall in structural zone (with bottom boon connection to stud)
G4 1 114   Plan of ext wall in structural zone (without boom boom connection to stud)
G4 1 116   Section though external wall (without bottom boom connection to stud)
G4 1 117   Section through external wall (with bottom boom connection to stud)
G4 1 118   Plan of external corner - room zone
G4 1 119   Plan of internal corner
G4 1 120   Plan of external wall
G4 1 121   Section through upper floor
G4 1 122   Plans of movement joints
G4 1 123   Plan of movement joint at int. corner
G4 1 124   Plan of structural movement joint at internal corner
G4 1 125   Section through upper floor/roof at block junction
G4 1 128   Section through head of re-entrant opening greater than 2400mm wide
G4 1 129   Section through head of wall in re-entrant
G4 1 140   Section through kerb at ground level
G4 2 100   Coping range
G4 2 110   Coping fixings
G5 1 101   Section through window head
G5 1 102   Section through window head showing roller awning blind
G5 1 104   Plan of roller awning blinds
G5 1 110   Plan of window reveal
G5 1 111   Plan of coupled windows
G5 1 113   External corner column casing-window/window. (British gypsum/brick)
G5 1 114   Plan of window at internal corner
G5 1 118   Plan of movement joint at internal corner with window
G5 1 120   Section through sill/standard window
G5 1 121   Section through sill - high level window
G5 1 122   Section through full height window at ground level
G5 1 123   Section through sill at block junction
G5 1 124   Plan of window sill at block junction
G5 1 130   Elevation of window sub-frame
G5 1 140   Plan details of window inserts
G5 1 141   Sectional details of window inserts - fixed single glazed
G5 1 142   Sectional details of window inserts - fixed double glazed
G5 1 143   Sectional details of window inserts - top hung single glazed
G5 1 144   Sectional details of window inserts - top hung double glazed
G5 1 145   Sectional details of window inserts - vertical sliding single glazed
G5 1 146   Sectional details of window inserts - vertical sliding double glazed
G5 1 201   Section through head of 2400mm high door
G5 1 202   Plan of 2400mm high single door
G5 1 203   Plan of 2400mm high double door
G5 1 204   Section through head of 2700mm high door
G5 1 205   Plan of 2700mm high single door
G5 1 207   Section through door head in re-entrant
G5 1 210   Plan of door jamb
G5 1 212   Plan of door coupled to window
G5 1 220   Section through external door threshold
G5 1 221   Section through door threshold at block junction
G5 1 222   Plan of door threshold at block junction (plant room)
G5 1 230   Elevation of door sub-frame
G5 2 100   Lintel range and details
G5 2 200   Door and window sub-frame range 2400mm ceiling height
G5 2 201   Door and window sub-frame range 2700mm ceiling height
G5 2 209   Window sub-frame details (with blind box)
G5 2 210   Window sub-frame details (without blind box)
G5 2 211   Door sub-frame details
G5 2 300   Aluminium window insert range
G5 2 400   External door range
   
 