Oxford Method Research Programme

Drawings ( on-line Library )

22 Series Drawings - 6M Oxford Method
   
  22 100 105 Partitions - typical plans
  22 110 113 Partitions - typical vertical sections
  22 114   Column casing - 1 hr fire rating
  22 120 139 Internal partitions - typical junctions
  22 140 149 Internal partitions /columns/movement joints
  22 140 152 Internal partitions/columns/movement joints
  22 160 162 Mounted electrical outlets for 100mm partitions
  22 163 164 Mounted electrical outlets for 200mm partitions
  22 165   Mounted electrical outlets for 200mm partitions
  22 170 175 Details of rectangular access panels
  22 180 183 Sections showing details of partitions around sanitary assembly back panels
  22 190 195 Plans showing details of partitions around sanitary assembly back panels
  22 200 205 Details of ply fixing panels for sanitary assemblies
  22 230   Glazed openings range drawing
  22 235 238 Single glazed openings - typical details
  22 240 243 Double glazed openings - typical details
  22 250 253 Door openings in partitions - typical details
  22 270 288 Openings in partitions - typical junctions
  22 610 615 Details of fire resisting blockwork walls
  22 620 625 Details of fire resisting blockwork walls
  22 680 684 Details of sanitary assembly back panels in internal blockwork walls
  22 710 711 Details of cavity barrier (mandoval) at ceiling level
  22 730 732 Details of cavity barriers at slab and tie level
   
 
R2 Series Drawings - 6M Oxford Method
   
R2 0 111   Internal partitions - typical junctions (2)
R2 0 120   Internal partitions/columns/movement joints typical junctions
R2 0 130   Lead-lined partitions - typical junctions
R2 0 135   Lead line partitions/column casings - typical junctions
R2 1 031   Movement joints in 100 partitions - elevations
R2 1 032   Movement joints in 200 partitions - elevations
R2 1 115   Partitions - typical plans
R2 1 120   Partitions - typical vertical sections
R2 1 125   X-ray partitions - typical sections
R2 1 127   200mm x-ray partitions - typical plans
R2 1 131   Movement joints in 200mm partitions - plans
R2 1 140   Details of rectangular access panels
R2 1 141   Details of circular access panel
R2 1 150   Plan of pipe duct at column/partition
R2 1 160   Mounted electrical outlets for 100mm partitions
R2 1 166   Mounted electrical outlets for 200mm partitions (2)
R2 1 170   Mounted electrical outlets for external wall lining
R2 1 180   Mounted electrical outlets for 100mm partitions in x-ray zones
R2 1 185   Mounted electrical outlets for 200mm partitions in x-ray zones (1)
R2 1 186   Mounted electrical outlets for 200mm partitions in x-ray zones (2)
R2 1 190   Details of ply fixing panel for typical washbasin
R2 1 192   Details of ply fixing panel for WC
R2 1 194   Details of ply fixing panel for urinal
R2 1 196   Fixing of wall mounted taps
R2 1 198   Plywood back board for lavatory basin mounting
R2 1 205   Plan showing details of partition around sanitary assembly back panel
R2 1 210   Section showing details of partition around sanitary assembly back panels
   
 

 

©2004 Oxford Method Royalties Management Group