skip to:
page content
|
links on this page
|
site navigation
|
footer (site information)
Oxford Method Research Programme
Home
2M/3M History
6M Development
Programme
Photographs
Drawings
Inso SpA
Information
search
Drawings ( on-line Library )
2M/3M Alphabetical
External
Internal
Drainage/Services
6M Alphabetical
External
Drainage/Services
Miscellaneous
6M Internal
Ceilings
6M Drawings
Internal Columns, Partitions & Fixings
22 Series Drawings - 6M Oxford Method
22
100
105
Partitions - typical plans
22
110
113
Partitions - typical vertical sections
22
114
Column casing - 1 hr fire rating
22
120
139
Internal partitions - typical junctions
22
140
149
Internal partitions /columns/movement joints
22
140
152
Internal partitions/columns/movement joints
22
160
162
Mounted electrical outlets for 100mm partitions
22
163
164
Mounted electrical outlets for 200mm partitions
22
165
Mounted electrical outlets for 200mm partitions
22
170
175
Details of rectangular access panels
22
180
183
Sections showing details of partitions around sanitary assembly back panels
22
190
195
Plans showing details of partitions around sanitary assembly back panels
22
200
205
Details of ply fixing panels for sanitary assemblies
22
230
Glazed openings range drawing
22
235
238
Single glazed openings - typical details
22
240
243
Double glazed openings - typical details
22
250
253
Door openings in partitions - typical details
22
270
288
Openings in partitions - typical junctions
22
610
615
Details of fire resisting blockwork walls
22
620
625
Details of fire resisting blockwork walls
22
680
684
Details of sanitary assembly back panels in internal blockwork walls
22
710
711
Details of cavity barrier (mandoval) at ceiling level
22
730
732
Details of cavity barriers at slab and tie level
Top of Page
R2 Series Drawings - 6M Oxford Method
R2
0
111
Internal partitions - typical junctions (2)
R2
0
120
Internal partitions/columns/movement joints typical junctions
R2
0
130
Lead-lined partitions - typical junctions
R2
0
135
Lead line partitions/column casings - typical junctions
R2
1
031
Movement joints in 100 partitions - elevations
R2
1
032
Movement joints in 200 partitions - elevations
R2
1
115
Partitions - typical plans
R2
1
120
Partitions - typical vertical sections
R2
1
125
X-ray partitions - typical sections
R2
1
127
200mm x-ray partitions - typical plans
R2
1
131
Movement joints in 200mm partitions - plans
R2
1
140
Details of rectangular access panels
R2
1
141
Details of circular access panel
R2
1
150
Plan of pipe duct at column/partition
R2
1
160
Mounted electrical outlets for 100mm partitions
R2
1
166
Mounted electrical outlets for 200mm partitions (2)
R2
1
170
Mounted electrical outlets for external wall lining
R2
1
180
Mounted electrical outlets for 100mm partitions in x-ray zones
R2
1
185
Mounted electrical outlets for 200mm partitions in x-ray zones (1)
R2
1
186
Mounted electrical outlets for 200mm partitions in x-ray zones (2)
R2
1
190
Details of ply fixing panel for typical washbasin
R2
1
192
Details of ply fixing panel for WC
R2
1
194
Details of ply fixing panel for urinal
R2
1
196
Fixing of wall mounted taps
R2
1
198
Plywood back board for lavatory basin mounting
R2
1
205
Plan showing details of partition around sanitary assembly back panel
R2
1
210
Section showing details of partition around sanitary assembly back panels
Top of Page